| Chambers | 3110-585 |
Pull Rod
| Upper Pullrod, Type Cm (5/8 in connection with 1/4 in clevis pin) to Pneumatic Connection.
Capacity: 1 kN (100 kgf, 225 lbf)
Effective length: 361 mm (14.2 in). Diameter: 31.7 mm (1.25 in).
Chamber filler plug not included; Ref. 3110-525
Checknut not used.
| 1 |
Contact Instron About Item
|
| Chambers | 3110-710 |
Push Pull Rod
| Push/Pull Rod.
Type Om to Of. 322mm (12.7 inch) long. | 1 |
Contact Instron About Item
|
| Couplings | 2501-094 |
Tension Coupling
| Tension Coupling, Type Om (12 mm connection with 6 mm clevis pin) to Cf (5/8 in connection with 1/4 in clevis pin). Capacity: 2 kN. | 1 |
Contact Instron About Item
|
| Couplings | 2501-157 |
Tension Coupling
| Tension Coupling, Type OOm (6 mm connection with 2.6 mm clevis pin) to Cf
(5/8 in connection with 1/4 in clevis pin). | 1 |
Contact Instron About Item
|
| Couplings | 2501-351 |
Coupling for 2713-006 grips
| Adaptor set for 2713-006 grips to Instron machines. Includes two Type Om, one Type Dm Adapters. | 1 |
Contact Instron About Item
|
| Couplings | 8005-042 |
Attachment Kit
| Attachment Kit. Type IIm LH (M48X2) to IIm RH (M48X2). Includes Wedge
Washers. | 2 |
Contact Instron About Item
|
| Extensometers | LCR-UEX-2630-105 |
2630-105
| 25 mm gauge length, +/-10% travel (Static) | 4 |
Contact Instron About Item
|
| Extensometers | LCR-UEX-2630-106 |
2630-106
| 25mm gauge length 10% travel (Static) | 1 |
Contact Instron About Item
|
| Extensometers | LCR-UEX-2630-107 |
2630-107
| 25mm gauge length 100% travel (Static) | 2 |
Contact Instron About Item
|
| Extensometers | LCR-UEX-2640-010 |
2640-010
| 25mm guage length 10mm travel (Averaging extensometer for "r" value of sheet metal) | 2 |
Contact Instron About Item
|
| Extensometers | U380 |
B3M
| Reconditioned Model B3M extensometer, 1" GL, 2% Measuring Range
Rounds: .05" to .505"
Flats: .005" to 0.500" thick x 0.500" wide | 1 |
Contact Instron About Item
|
| Extensometers | U383 |
PS6M
| Reconditioned Model PS6M | 1 |
Contact Instron About Item
|
| Extensometers | U415 |
Series E
| Reconditioned Series E Extensometer. 2" GL with +50%/-25% travel | 1 |
Contact Instron About Item
|
| Extensometers | U592 |
W-6280-8
| Long GL (8") Extensometer. 12.5% Strain.
Rounds: 0 to 1"
Flats: 0 to 0.5" thick x 1.25" wide | 1 |
Contact Instron About Item
|
| Extensometers | U594 |
M300
| Used M300 Automatic Extensometer for use on a LX system. GL Range: 10mm to 200mm.
Rounds: 80mm max
Flats: 30mm thick & 50mm wide max | 1 |
Contact Instron About Item
|
| Extensometers | U622 |
Series E
| Extensometer E-Series I3543, 250mm guage length, 100mm travel | 1 |
Contact Instron About Item
|
| Faces | 2702-004 |
Faces
| Smooth faces. 1 x 1 inch
Used with grips
2712-002, 2732-001, 2710-001
B Style | 1 |
Contact Instron About Item
|
| Faces | 2702-009 |
Faces
| Faces, Serrated. 50 mm wide x 25 mm high (2 x 1 in.). Set of 4 faces.
For 2710-001, 101, 102, 2712-002, 014, 019, and 2732-001, 006
Pneumatic Side Action Grips, and Screw Side Action Grips. | 1 |
Contact Instron About Item
|
| Faces | 2702-031 |
Faces, Smooth
| Faces, Smooth Ground. 25 mm wide x 25 mm high (1 x 1 in.) . Set of 4 faces.
For 2710-002, 103, 104, 2712-003, 004, 015, 016, 018, 020, and 2732-003,
004, 008, 009
Pneumatic Side Action Grips, and Screw Side Action Grips. | 1 |
Contact Instron About Item
|
| Faces | 2702-033 |
Faces, Serrated. 25 mm wide x 25 mm high
| Faces, Serrated. 25 mm wide x 25 mm high (1 x 1 in.)
Set of 4 faces.
For 2710-002, 103, 104, 2712-003, 004, 015, 016, 018, 020, and 2732-003,
004, 008, 009
Pneumatic Side Action Grips, and Screw Side Action Grips. | 2 |
Contact Instron About Item
|
| Faces | 2702-034 |
Faces
| Faces, Smooth Ground. 75 mm wide x 25 mm high (3 x 1 in.) For 2712-003, 2732-003, 2712-004, 2732-004, 2712-015, 2712-016 Pneumatic Side Action Grips, and 2710-002, S1-15455 Screw Action Grips. Set of 4 faces. | 1 |
Contact Instron About Item
|
| Faces | 2702-042 |
Faces
| Hi temp faces. 1 x 1 inch.
Used with grips
2712-002, 2732-001, 2710-001
B Style | 2 |
Contact Instron About Item
|
| Faces | 2702-106 |
Faces, Smooth
| Faces, Smooth Ground. 25 mm x 25 mm (1 x 1 in). Specimen thickness: 0 -
20 mm. For 2712-017 Pneumatic Side Action Grips and 2712-012 Pneumatic
Side Action Grips. Set of four faces. | 1 |
Contact Instron About Item
|
| Faces | 2702-130 |
Faces
| Faces, Smooth Ground. 25 mm wide x 25 mm high (1 x 1 in). For 2710-004
Screw Action Grips. Set of four faces. | 1 |
Contact Instron About Item
|
| Faces | 2702-132 |
Faces, Rubber Coated
| Faces, Rubber Coated. 25 mm wide x 25 mm high (1 x 1 in). For 2710-004
Screw Action Grips. Set of four faces. | 1 |
Contact Instron About Item
|
| Faces | 2702-140 |
Faces
| Jaw faces, smooth-ground, 50 mm wide x 30 mm high (2.0 in x 1.2 in).
For specimens up to 15 mm (0.6 in) thickness.
For 2710-203, 2710-204, 2710-205 grips. | 1 |
Contact Instron About Item
|
| Faces | 2702-142 |
Jaw Faces
| Jaw faces, rubber-coated, 50 mm wide x 30 mm high (2.0 in x 1.2 in).
For specimens up to 15 mm (0.6 in) thickness.
For 2710-203, 2710-204, 2710-205 grips | 1 |
Contact Instron About Item
|
| Faces | 2703-071 |
Faces
| Threaded faces. 16T per inch
16mm to 19mm(0.625 to 0.75 inch) opening
Used with grips 2716-002, 2736-002 | 1 |
Contact Instron About Item
|
| Faces | 2703-171 |
Faces
| Serrated faces. 25mm
Use with grips
2716-016, 2716-017 | 1 |
Contact Instron About Item
|
| Faces | 2703-182 |
Faces
| Faces, Vee Serrated. Specimen thickness range: 6-17.8 mm.
For 2716-110, 111, 120, 121 Pneumatic Wedge Action Grips.
Set of four. | 1 |
Contact Instron About Item
|
| Faces | 2703-555 |
Faces
| Serrated faces. 100mm wide
25 to 32mm (1.0 to 1.25inch) opening
Used with grips 2742-524 | 1 |
Contact Instron About Item
|
| Faces | W-5181-A |
Faces
| Faces, Flat Serrated 1.25 mm pitch grooves (20 TPI), 70 mm (2.75 in) wide.
Specimen Thickness: 0 - 15 mm (0 - 0.59 in).
Jaw Faces for W-5180, W-5380 WEDGE GRIP bodies and 150DX-G7(A thru-D), 300DX-G7 (A thru D)
crossheads | 1 |
Contact Instron About Item
|
| Faces | W-5181-B |
Faces
| Faces, Flat Serrated 1.25 mm pitch grooves (20 TPI), 70 mm (2.75 in) wide.
Specimen Thickness: 15 - 30 mm (0.59 - 1.18 in)
For W-5180, W-5380 bodies and 150DX-G7, 300DX-G7 crossheads | 1 |
Contact Instron About Item
|
| Faces | W-5181-C |
Faces
| Faces, Flat Serrated 1.25 mm pitch grooves (20 TPI), 70 mm (2.75 in) wide.
Specimen Thickness: 30 - 45 mm (1.18 - 1.77 in)For W-5180, W-5380 bodies and 150DX-G7, 300DX-G7 crossheads | 1 |
Contact Instron About Item
|
| Faces | W-5185-B |
Faces
| Faces, Vee Serrated 1.25 mm pitch grooves (20 TPI).
Specimen Diameter: 5 - 15 mm (0.196 - 0.59 in.
Jaw Faces for W-5180, W-5380 WEDGE GRIP bodies and 150DX-G7(A thru-D), 300DX-G7 (A thru D)
crossheads | 1 |
Contact Instron About Item
|
| Faces | W-5185-C |
Faces
| Faces, Flat Serrated 1.25 mm pitch grooves (20 TPI), 70 mm (2.75 in) wide.
Specimen Thickness: 30 - 45 mm (1.18 - 1.77 in.
Jaw Faces for W-5180, W-5380 WEDGE GRIP bodies and 150DX-G7(A thru-D), 300DX-G7 (A thru D)
crossheads | 1 |
Contact Instron About Item
|
| Faces | W-5185-D |
Faces
| Faces, Vee Serrated 2.5 mm pitch grooves (10 TPI).
Specimen Diameter: 30 - 45 mm (1.18 - 1.77 in)
Note: Maximum Jaw face separation fully open-front grip loading is 37 mm
(1.46 in). Specimens of greater diameter require end loading.
Jaw Faces for W-5180, W-5380 WEDGE GRIP bodies and 150DX-G7(A thru-D), 300DX-G7 (A thru D)
crossheads | 1 |
Contact Instron About Item
|
| Fixtures | 2810-195 |
Ball Burst
| Ball Burst Compression Fixture. Capacity: 10 kN (2000 lb, 1000 kg). Upper fitting: Type Om (12 mm connection with 6 mm clevis pin). Lower: Type Dm (1.25 in connection with 1/2 in clevis pin). Conforms to ASTM D3787, D6797, and Federal Standard 191A. | 1 |
Contact Instron About Item
|
| Fixtures | 2810-411 |
Micro 3 Point Bend Fixture
| Micro 3 Point Bend Fixture
Adjustable Span: 3 mm to 10 mm.
Capacity 1 kN (225 lb, 100 kgf).
Temperature range: -75°C to 300°C (-103°F to 572°F). Maximum specimen
width: 20 mm (0.79 in).
Upper and lower fittings: Type Om (12 mm connection with 6 mm clevis pin).
ref. S4843A | 1 |
Contact Instron About Item
|
| Fixtures | CP101000 |
ASTM C496-04
| ASTM C496-04
Splitting Tensile Strength of Cylindrical Concrete Specimens
Upper fitting: 0.5 in clevis pin
Upper anvil EL: 425 mm
Upper anvil weight: 21 Kg
Lower fitting: 4 x M10 on 90 x 280
accessory mounting pattern.
Base plate: 317.5 W x 457.2 D x
51m thick
Base plate weight: 58 Kg
| 1 |
Contact Instron About Item
|
| Fixtures | PR10754-8 |
Dies Shear fixture
| Die Shear fixture with 10 mm.
1 kN Capacity | 1 |
Contact Instron About Item
|
| Grips | 2710-001 |
Screw Action Grips
| Screw Side Action Grips. Capacity: 100 N (20 lb, 10 kg).
Temperature range: -73 °C to 123 °C (-100 °F to 263 °F).
Maximum specimen thickness: *6.35 mm (0.25 in)
*Reduced by 0.9 mm (0.036 in) with rubber coated faces.
Upper fitting: Type Bm (1/2 in connection with 3/16 in clevis pin).
Lower fitting: Type Dm (1.25 in connection with 1/2 in clevis pin).
Requires faces. | 3 |
Contact Instron About Item
|
| Grips | 2710-101 |
Screw Side Action Grip
| Advanced Screw Side-Action Grips. Capacity: 100 N (10 kgf, 20 lbf).
Temperature Range: -70 °C to +125 °C (-94 °F to +257 °F)
Upper and lower fittings: Type Om (12 mm connection with 6 mm clevis pin)
Features:
- Dual screw actuation with graduated cylinders
- Snap-on jaw face mechanism with self-alignment
- Wide opening suitable for specimen thicknesses up to 30 mm (1.2 in)
Requires jaw faces | 1 |
Contact Instron About Item
|
| Grips | 2710-113 |
Advanced Screw Side-Action Grips.
| Advanced Screw Side-Action Grips. Capacity: 1 kN (100 Kgf, 225 lbf).
Temperature Range: -70 °C to +125 °C (-94 °F to +257 °F)
Upper and lower fittings: Type Om (12 mm connection with 6 mm clevis pin)
Features:
- Dual screw actuation with graduated cylinders
- Slide-on jaw face mechanism with vertical-alignment
- Wide opening suitable for specimen thicknesses up to 36 mm (1.4 in)
Requires jaw faces | 1 |
Contact Instron About Item
|
| Grips | 2710-116 |
Advanced Screw Side-Action Grips.
| Advanced Screw Side-Action Grips. Capacity: 10 kN (1000 Kgf, 2250 lbf).
Temperature Range: -70 °C to +125 °C (-94 °F to +257 °F)
Upper and lower fittings: 0.5 in clevis pin, male.
Features:
- Dual screw actuation with graduated cylinders
- Slide-on jaw face mechanism with vertical-alignment
- Wide opening suitable for specimen thicknesses up to 46 mm (1.8 in)
Requires jaw faces | 2 |
Contact Instron About Item
|
| Grips | 2710-205 |
Jaw Faces
| Basic Screw Side-Action Grips. Capacity: 5 kN (500 Kgf, 1125 lbf).
Temperature Range: 10 °C to 40 °C (50 °F to 100 °F)
Upper fitting: Type O (12 mm connection with 6 mm clevis pin)
Lower fitting: Type D (1.25 in connection with 1/2 in clevis pin)
Suitable for specimen thicknesses up to 15 mm (0.6 in)
Requires jaw faces | 1 |
Contact Instron About Item
|
| Grips | 2711-001 |
Fiber Clamps
| Fiber Clamps. 5N
Upper Type A Lower Type D | 4 |
Contact Instron About Item
|
| Grips | 2711-006 |
Fiber Clamps, Lever Action.
| Fiber Clamps, Lever Action. Capacity: 5 N (1.10 lb, 500gm).
Temperature range: -10 °C to 100 °C (14 °F to 212 °F).
Upper and lower fittings: Type Om (12 mm connection with 6 mm clevis pin).
Includes a Type A (hook) for the upper grip. | 1 |
Contact Instron About Item
|
| Grips | 2712-001 |
Pneumatic Side Action Grips
| Pneumatic Side Action Grips. Capacity: 5 N (1.0 lb, 500gm).
Temperature range: -29 °C to 80 °C (-20 °F to 176 °F).
Maximum specimen thickness: 3.96 mm (0.156 in).
Upper fitting: Type A (Hook).
Lower fitting: Type Dm (1.25 in connection with 1/2 in clevis pin).
Includes one pair of 9.5 x 9.5 mm smooth faces.
Requires an Automatic Air Control Kit or Pneumatic Foot Switch | 2 |
Contact Instron About Item
|
| Grips | 2712-013 |
Pneumatic Side Action Grips
| Pneumatic Side Action Grips. Capacity: 5 N (1.0 lb, 500gm).
Temperature range: -29 °C to 80 °C (-20 °F to 176 °F).
Maximum specimen thickness: 3.96 mm (0.156 in).
Upper and lower fittings: Type Om (12 mm connection with 6 mm clevis pin).
Includes 9.5 x 9.5 mm smooth faces.
Requires an Automatic Air Control Kit or Pneumatic Foot Switch | 2 |
Contact Instron About Item
|
| Grips | 2712-019 |
Pneumatic Side Action Grips.
| Pneumatic Side Action Grips. Capacity: 250 N (50 lb, 25 kg).
Temperature range: -29 °C to 80 °C (-20 °F to 176 °F).
Maximum specimen thickness: *3.175 mm (0.125 in)
*Reduced by 0.9 mm (0.036 in) with rubber coated faces.
Upper and lower fittings: Type Om (12 mm connection with 6 mm clevis pin).
Equiped with manual air switch and check nuts.
Requires faces and an Air Distribution Kit.
An Automatic Air Control Kit or Footswitch is recommended. | 4 |
Contact Instron About Item
|
| Grips | 2712-020 |
Pneumatic Action Grips
| Pneumatic Side Action Grips. Capacity: 1 kN (200 lb, 100 kg).
Temperature range: -29 °C to 80 °C (-20 °F to 176 °F).
Maximum specimen thickness: *6.35 mm (0.25 in)
*Reduced by 1.6 mm (0.062 in) with rubber coated faces.
Upper and lower fittings: Type Om (12 mm connection with 6 mm clevis pin).
Equipped with manual air switch and check nuts.
Requires faces and an Air Distribution Kit.
An Automatic Air Control Kit or Footswitch is recommended.
Maximum face height: 38 mm (1.5 in) | 5 |
Contact Instron About Item
|
| Grips | 2712-041 |
Pneumatic Side Action Grips.
| Pneumatic Side Action Grips. Capacity: 1 kN (100 kg, 225lb).
Temperature range: -20 °C to +100 °C (-4 °F to +212°F).
Maximum specimen thickness: 13mm (0.5 in)*
*Depends on jaw faces selected
Upper and lower fittings: 6 mm clevis pin, male | 1 |
Contact Instron About Item
|
| Grips | 2712-046 |
Pneumatic Side Action Grips.
| Pneumatic Side Action Grips. Capacity: 10 kN (1000 kg, 2250 lb,).
Temperature range: -20 °C to +100 °C (-4 °F to +212°F).
Maximum specimen thickness: 26mm (1 in)*
*Depends on jaw faces selected
Upper and lower fittings: 0.5 in clevis pin, male.
Requires jaw faces and an Air Distribution Kit.
Optional Air Control Kit with footswitch is available. | 1 |
Contact Instron About Item
|
| Grips | 2713-003 |
Roller Grips
| Self Tightening Roller Grips, Capacity: 2 kN (450 lb, 200 kg).
Temperature range: -70 °C to +250 °C
Upper fitting: Type Cm (5/8 in connection with 1/4 in clevis pin).
Lower fitting: Type Dm (1.25 in connection with 1/2 in clevis pin).
For Elastomeric Samples. | 1 |
Contact Instron About Item
|
| Grips | 2715-002 |
Capstan grip faces
| Smooth faces for 2715-001 | 1 |
Contact Instron About Item
|
| Grips | 2716-010 |
Mechanical Wedge grip
| Wedge Action Grips, Capacity: 5 kN (1,000 lb, 500 kg).
Temperature range: -150 °C to 250 °C (-240 °F to 480 °F).
Maximum specimen size is face determined.
Upper and lower fittings: Type Dm. (1.25 in connection with 1/2 in clevis pin).
Requires faces | 1 |
Contact Instron About Item
|
| Grips | 2716-015 |
Wedge Action Grips
| Wedge Action Grips, Capacity: 30 kN (6,700 lb, 3,000 kg).
Temperature range: -70 °C to 250 °C (-100 °F to 480 °F).
Maximum specimen size is face determined.
Upper and lower fittings: Type Dm (1.25 in connection with 1/2 in clevis pin).
Requires faces. | 1 |
Contact Instron About Item
|
| Grips | 2716-016 |
Wedge Action grips
| Wedge Action Grips. Capacity: 1 kN (200 lb, 100 kg).
Temperature range: -10 °C to 100 °C (14 °F to 212 °F).
Maximum specimen thickness: 6.35 mm (0.25 in).
Upper and lower fittings: Om (12 mm connection with 6 mm clevis pin).
Includes 19 mm (0.75 x 0.75) in serrated faces (2703-171). | 1 |
Contact Instron About Item
|
| Grips | 2716-110 |
Wedge Grip, Pneumatic
| Pneumatic Wedge Action Grips. Capacity: 100 kN (20,000 lb, 10,000 kg).
Upper fitting: Type 1m (34 mm connection with 16 mm clevis pin).
Lower fitting: (4) M16 x 150.
Maximum specimen thickness: 40 mm (flat).
Maximum specimen width: 75 mm (flat).
Maximum specimen diameter: 50 mm (round).
Clamping length: 70 mm.
Temperature range: ambient only.
Requires faces and an Air Distribution Kit.
An Automatic Air Control Kit or Footswitch is recommended. | 1 |
Contact Instron About Item
|
| Grips | 2752-005 |
BioPuls Submersible Pneumatic Side Action Grips
| BioPuls Submersible Pneumatic Side Action Grips
Standard features include:
- Designed specifically for use with BioPuls bath
- Rated capacity: 250 N (25 kg, 50 lb)
- Maximum jaw face opening: 10mm
- Manufactured out of Teflon sealed, hard-coated
aluminum to prevent corrosion
- Extremely light-weight for compatibility with 5.0 N load
cell
- Open front design to facilitate specimen loading
- Single cylinder pneumatic clamping with follow-up action
to reduce specimen slippage
- Interchangeable faces to accommodate a variety of
faces
- Adjustable gripping force when used with pressure gage
- Upper and lower fittings: M6 screw (Type Om optional)
- Catalog number includes set of two grips
- Requires 2701-004 pneumatic footswitch or 2701-065
grip control for operation of grips
Note - 26941 Grips do not include faces.
2752-105 Type O adapter kit required for use of grips without 3130-100
BioPuls Bath | 1 |
Contact Instron About Item
|
| Grips | CP103444 |
Hydraulic Wedge Action Grip
| Hydraulic Wedge Action Grips. Capacity 300 kN (67,500 lbf, 30,000 kgf)
Specimen Range:
- Flats: 0 - 50 mm thick (0 - 2.0 in) x 70 mm (2.75 in) wide
- Rounds: 3 - 40 mm (0.118 - 1.57 in) diameter
Minimum Specimen Length without the use of an extensometer is 270 mm
(10.63 in)
Ambient temperature use only.
Upper and Lower Fittings: Type IIfRH (M48 x 2)
Weight Per Grip Body 123 kg (270 lb)
Grip Body Dimensions W x L x D: 445 x 302 x 127 mm (17.5 x 11.875 x 5 in)
Effective Length using standard threaded mounting:
Upper - 329 mm (13.0 in)
Lower - 352 mm (13.8 in)
Grip faces sold separately use: W-5181 & W-5185 series grip faces
Notes:
1) Hydraulic hoses, manifolds and mounting hardware when purchased with a
new 300LX or 300KN testing system are provided. (Select mounting options
corresponding to load frame and test space option of the machine grips are to
be used on. Consult IPG Business team for all other applications.)
2) Note: If integrating these grips on an LX frame, the frame must be
configured with a minimum of 300 mm (1 foot) of extended height in order to
accomodate calibration fixtures. | 1 |
Contact Instron About Item
|
| Grips | U593 |
W-5021 & W-5012
| Used 100kN (22,500 Lbs) T-Grip Bodies & flat jaws (16 TPI diamond cut). Flats: Up to 1/2" thick x 1" wide. | 1 |
Contact Instron About Item
|
| Grips | U617 |
W-5072
| Used 60K Lbs Open Front T-Grips. 1-1/2-6 female mounting thread, crank & pinion actuated, 80 Lbs per holder, jaws not included. | 1 |
Contact Instron About Item
|
| Grips | W-1409-A |
600DX, or 120HVL Flat Grip Jaw Set
| 50% OFF SALE THROUGH DECEMBER 15TH. NEW OLD STOCK - LIST PRICE - $2080, ON SALE FOR $1040!!!
Set of (4) wedge grip jaws for flat specimens from 0 to 45 mm (1.75 in) thick by up to 70 mm (2.75 in) wide. Tooth Profile: Diamond cut, 16 TPI (teeth per inch) | 2 |
Contact Instron About Item
|
| Grips | W-1563 |
200 HVL Grips For Round Specimens
| 50% OFF SALE THROUGH DECEMBER 15TH. NEW OLD STOCK - LIST PRICE - $3640, ON SALE FOR $1820!!!
Set of (4) Vee wedge grip jaws for round specimens from 0.5 in (12.7 mm) to 2.25 in (57 mm) diameter. Tooth Profile: Horizontal cut, 16 TPI (teeth per inch)
| 2 |
Contact Instron About Item
|
| Load Cells | LCR-UEX-2519-106 |
2519-106
| 2kN S-Beam type load cell | 3 |
Contact Instron About Item
|
| Load Cells | LCR-UEX-2525-815 |
2525-815
| 2.5 N Drop Through Static | 3 |
Contact Instron About Item
|
| Load Cells | LCR-UEX-2530-439 |
2530-439
| 5 N Low Profile Static | 6 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2519-101 |
2519-101
| 10N S-Beam Static | 11 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2519-102 |
2519-102
| 50N S-Beam Static | 9 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2519-103 |
2519-103
| 100N S-Beam Static | 13 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2519-107 |
2519-107
| 5kN S-Beam Static | 6 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2525-804 |
2525-804
| 10kN Drop Through Static | 2 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2525-805 |
2525-805
| 5kN Drop Through Static | 1 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2525-808 |
2525-808
| 10N Drop Through Static | 2 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2527-100 |
2527-100
| 50kN Sandwich Style Dynamic (Dynacell) | 1 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-405 |
2530-405
| 5kN Low Profile Static | 13 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-427 |
2530-427
| 100N Low Profile Static | 3 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-428 |
2530-428
| 10N Low Profile Static | 1 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-443 |
2530-443
| 10kN Low Profile Static | 2 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-444 |
2530-444
| 30kN Low Profile Static | 5 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-445 |
2530-445
| 50kN Low Profile Static | 7 |
Contact Instron About Item
|
| Load Cells | W-5535-8 |
5kN Load Cell
| 50% OFF SALE THROUGH DECEMBER 15TH. NEW OLD STOCK - LIST PRICE - $3050, ON SALE FOR $1525!!!
Heavy Duty Tension/Compression Load Cell, Capacity 5 kN (500 kg, 1,100 lb.)
-Mounting, and adapter connection, M16 female
- Minimum 300% overload capacity
- Integral load stops minimize chance of cell damage during overload conditions.
- Equipped with 25 pin type D style connector for 3300, or 5500 test systems
| 1 |
Contact Instron About Item
|
| Load Cells | W-5535-9 |
10kN Load Cell - New
| 50% OFF SALE THROUGH DECEMBER 15TH. NEW OLD STOCK - LIST PRICE - $3280, ON SALE FOR $1640
Heavy Duty Tension/Compression Load Cell, Capacity 10 kN (1,000 kg, 2,200 lb.)
- Accuracy +/- 0.5% of reading from 1% to 100% of load cell capacity when used with SF Series Spring Testers
- Mounting connection, M16 female
- Adapter connection M16 female
- Minimum 300% overload capacity
- Integral load stops minimize chance of cell damage during overload conditions.
| 1 |
Contact Instron About Item
|
| Machines | 4201 |
4201
| Reconditioned Instron Model 4201 Table Top Electromechanical Test System. Capacity of 1,125 lbs. (5 kN) with 3300 electronics, load cell and load cell adaptor. | 3 |
Contact Instron About Item
|
| Machines | 4464 |
4464
| Reconditioned Instron Model 4464 Electromechanical Test System. Capacity of 450 Lbs (2kN) with 3300 electronics, load cell and load cell adaptor. | 5 |
Contact Instron About Item
|
| Machines | 60BTE |
60BTE
| Reconditioned Model 60BTE Universal Testing Machine designed to perform tension & compression tests. Capacity of 60,000 Lbs with IS Series control electronics. | 1 |
Contact Instron About Item
|
| Machines | 60HVL |
60HVL
| Reconditioned Model 60HVL Universal Testing Machine designed to perform tension & compression tests. Capacity of 60,000 Lbs with IS Series control electronics. | 1 |
Contact Instron About Item
|
| Platens | 2501-081 |
Platen
| Compression Platen. 150kN
127 mm (5 inch) diameter.
Type 1 1/2-12 inch RHm connection.
1 platen-No Flats | 1 |
Contact Instron About Item
|
| Platens | 2501-107 |
Platen
| Compression Platen. 50N
13 sq cm (2 sq inch) 40.6mm (1.6 inch) diameter.
Type Om connection | 1 |
Contact Instron About Item
|
| Platens | 2840-112 |
Platen
| Fatigue Rated Spherical Seat, Capacity 500kN (110 kip) Static / 250kN (56 kip)
Dynamic.
- For Use With 2840-118,-119 Or -110 Platens
- Includes adaptor to M30 x 2 right hand or M48 x 2 right hand compression
platen
- Mechanical interface: M48 x 2 right hand female thread
Quantity: 1 seat | 1 |
Contact Instron About Item
|